There are eleven different sizes of E-AddBlock.

EMC
EMC
G&B
G&B

Technical specifications

E-Addblock

There are eleven different sizes of E-AddBlock. By tearing off the wing-like inserts, which are of varying thickness, and inserting them in the main block it is possible to accommodate 66 different cable and pipe dimensions, from 3.5 mm to 69.5 mm. The inserts are fitted with a locating ridge that fits exactly into furrows in the main block. These stop the block from ”telescoping”. A seal using E-AddBlocks is as secure and tight as one using standard blocks. Both types can be combined in a transit, which makes the MCT Brattberg seal system very flexible. E-AddBlocks are all the same length as standard blocks, 60 mm. The width of standard blocks (measurement, see table) are 20, 30, 40, 60 or 90 mm.

E-Addblock Sizes
E-Addblock Instructions

Grounding and Bonding

E-blocks comply to grounding and bonding standards.

-CSA Std. C22.2 No. 4.1 - Grounding and Bonding Equipment
-CSA Std. C22.2 No. 18.3 - Conduit, Tubing and Cable Fittings
-CSA Std. C22.2 No. 182.3 - Special use attachment plugs, receptacles and connectors (as a guide)
-UL Std. 467 - Grounding and Bonding Equipment
-UL Std. 514B - Conduit, Tubing and Cable Fittings
-UL Std. 1977 - Component Connectors for use i Data, Signal, Control and Power applications

Standard

Anti-Rodent
GR/DWC-34/01/SEP 2007 & RDSO/SPN/204/2011

Train EN-45545
HL 1, HL 2, HL 3

Data

Trade name: 
MCT Brattberg E-AddBlock

Variations: 
See TECH SPECS

Lycron data

Read Lycron data sheet:
Data sheet Lycron


Lycron is halogen free and flame retardant.

 

For all approvals, please also see Certificates 

Instructions

EMC

  • All dimensions are exactly the same for the standard MCT Brattberg components.
  • All Insert Blocks are marked with yellow marking (see instructions).

Grounding and Bonding

  • For grounding & bonding applications standard presswedge or endpacking is sufficient. 
  • Series RGS, RGB, RGG, and E-RGP These products are primarily intended for grounding and bonding of communication, instrument, power, braid or wire armored cables and copper pipes, up to max. 1 AWG.
  • Plugs and Wraps are only for use in Grounding and Bonding applications, not EMC

Correct and safe installations

To achieve the highest standard of safety, a cable or pipe transit must be installed correctly. As there are many different types of frame – which may be either welded, bolted or glued into position – and insert block, it is essential that installers known when to use the most appropriate installation method.