Skip to Content

E-RGG

These cable and pipe transits are used in high-risk land-based environments to minimize danger by preventing the spread of fire, water, gas, chemicals and other hazards substances.

E-RGG provide the same sealing as the standard MCT Brattberg system but with added, built-in protection against electromagnetic pulse (due to lightning or nuclear blast) and interference (EMI), electronic sabotage (synthetic EMP) and static electricity.
E-RGG frame type is bolted onto a concrete wall or floor or a plaster board wall. It is manufactured from a 60x60x6 mm angle bar.

  • The E-RGG is also approved for grounding and bonding applications.
EI30-EI240
EI30-EI240
Nema 250
Nema 250
IP66/68
IP66/68
Bolted
Bolted
EMC
EMC
G&B
G&B

Benefits of MCT Brattberg E-systems

  • Protects against electrical and magnetic interference (EMI), “bugging”, electronic sabotage (SEMP) and static electricity (ESD).
  • Assists cable management.
  • Integral earthing between cables and wall screen.
  • Also seals the penetration against the passage of fire, water, gas, sound and environmental hazards.
  • Special E-Series for Grounding and Bounding
  • System can be dismantled and re-used.

Overview

E-RGG sizes

The standard transit is made of an angle bar 60x60x6 mm, in mild steel, stainless steel or aluminium. The mild steel transits are supplied with two types of surface finish, primer or galvanized. The internal width is always 120.5 ± 0.5.

Standard frames come in eight sizes: 1, 2, 3, 4, 5, 6, 7, and 8. 
The internal width can be 60.5 ± 1 (Size 1,3,5,7) or 120.5 ± 1 (2,4,6,8).

Note that there can be limitations in type-approvals & certificates, making certain sizes inapplicable

All the frames can be manufactured in combinations.

E-RGGO transit are of the same type as the E-RGG transits but with one of the ends removable which enables installation where cables already have been pulled.

For further technical information see tables in our Online Catalogue:

Performance

Resistance to fire:

Enclosure degree of protection Nema 250:
3R; 4X; 12 - Nema 250-1st

Enclosure degree of protection IP: 
IP65; IP66; IP67; IP68 2 meters 60 min - IEC 60529

 

Lycron data

Read Lycron data sheet:
Data sheet Lycron


Lycron is halogen free and flame retardant.

 

For all approvals, please also see Certificates 

Instructions

EMC

  • All dimensions are exactly the same for the standard MCT Brattberg components.
  • All Insert Blocks are marked with yellow marking (see instructions).

Grounding and Bonding

  • For grounding & bonding applications standard presswedge or endpacking is sufficient. 
  • Series E-RGS, E-RGB, E-RGG, and E-RGP These products are primarily intended for grounding and bonding of communication, instrument, power, braid or wire armored cables and copper pipes.
  • Plugs and Wraps are only for use in Grounding and Bonding applications, not EMC

Correct and safe installations

To achieve the highest standard of safety, a cable or pipe transit must be installed correctly. As there are many different types of frame – which may be either welded, bolted or glued into position – and insert block, it is essential that installers known when to use the most appropriate installation method.

For more information, please view following instructions, videos or download manuals as PDFs.

EMC Installation
Instructions 1
Instructions 2
Instructions 3

Download pdf instructions

On Land Catalogue ENG

 

Multiple frames

HORIZONTAL MULTIPLE FRAMES

Horizontal multiple frames are described by listing the frame type and size x the desired number of horizontal openings.
Designation (starting at bottom):
Frame type 6x4

VERTICAL MULTIPLE FRAMES

Vertical multiple frames are described by listing the bottom frame type and size + the next frame type and size.
Designation (starting at bottom):
(frame type) 6+6+4 and (frame type) 6+4+2


VERTICAL AND HORIZONTAL MULTIPLE FRAMES

List the entire vertical frames x the desired number of horizontal repetitions.
Designation (starting at bottom):
(frame type) 6+4+2x4


NOTE: All multiple frame designations must be preceded by the frame type.

NOTE: All multiple frame designations must be preceded by the frame type.

EMC and G&B Insert Blocks

E-Standard Block

E-Standard Block with EMC and G&B capabilities

Read more

E-Addblock

E-Addblock with EMC and G&B capabilities

Read more

E-Spareblock

E-Spareblock with EMC and G&B capabilities

Read more

Components

Stayplate

To be placed between each row of blocks.

Read more

STG Endpacking

Installed between compression plate and the top of the frame, completing the seal.

Read more

PTG Presswedge

The Presswedge compresses the system and completing the seal.

Read more

Lubricant

MCT Brattberg Lubricant for easier and safer installation.

Read more

E-PTG Presswedge

The Presswedge with EMC and G&B capabilites compresses the system and completing the seal.

Read more

E-STG Endpacking

Installed between compression plate and the top of the frame, completing the seal.

Read more