Skip to Content

RGG-O Ex

 

  • Fast delivery

  • Low lead time, always in stock

  • Openable and retrofit

 

EI30-EI240
EI30-EI240
Nema 250
Nema 250
IP66/68
IP66/68
Ex
Ex
RGG-O

Overview

RGG-O

  • Type approved cable transit for buildings
  • Can be casted in concrete
  • Assists cable management
  • Seals the penetration against the passage of fire, water, gas, sound and environmental hazards
  • Unlike other brands our system can be dismantled and re-used
  • Marked cable designation on blocks for increased safety
  • No adaptation of standard blocks needed

 

RGG-O frame type can be bolted onto concrete, plaster board wall or casted into a concrete wall or floor to protect against flooding, water and ingress.

The transit is made of two angle bars 60x6 and two gables in galvanized mild steel.
The standard height varies with the sizes - 2, 4, 6 or 8 (internal width 120.5 ± 1). Can be installed in horizontal combinations.
Please see information drawings for detailed data.

RGG-O have removable ends which enables installation where cables already have been pulled.

Benefits of MCT Brattberg Ex systems

  • Ex rated transit for hazardous environments
  • Assists cable management
  • Seals the penetration against the passage of fire, water, gas, sound and environmental hazards
  • Can be combined with special EMC modules and for Grounding and Bounding
  • Unlike other brands our system can be dismantled and re-used
  • Marked blocks for increased safety
  • No adaptation of standard blocks needed

 

The marking of the equipment and protective system

Group II Category 2GD Ex eb IIC Gb Ex tb IIIC Db Tamb (-60°C to+70°C)

 

 

 

 

 

 

 

 

 

Standard frames in four different
sizes: 2, 4, 6 and 8 which mark
different heights.
All have the same
width.

Performance

Resistance to fire:

Enclosure degree of protection Nema 250:
3R; 4X; 12 - Nema 250-1st

Enclosure degree of protection IP: 
IP65; IP66; IP67; IP68 2 meters 60 min - IEC 60529

 

Lycron data

Read Lycron data sheet:
Data sheet Lycron


Lycron is halogen free and flame retardant.

 

For all approvals, please also see Certificates 

Ex

  • Available only as equipment.

Component:
Component is not intended to be used alone and requires additional consideration when incorporated into other equipment or systems for use in explosive atmospheres (refer to IEC 60079-0)

  • All blocks marked with black or green marking.
  • Ex system combined with EMC has yellow marking on the front face (see EMC instructions) and black or green on the back.

Correct and safe installations

To achieve the highest standard of safety, a cable or pipe transit must be installed correctly. As there are many different types of frame – which may be either welded, bolted or glued into position – and insert block, it is essential that installers known when to use the most appropriate installation method.

For more information, please view following instructions, videos or download manuals as PDFs.

Instructions 1
Instructions 2
Instructions 3
How to install a MCT Brattberg RGS/RGB frame, vertical

Multiple frames

HORIZONTAL MULTIPLE FRAMES

Horizontal multiple frames are described by listing the frame type and size x the desired number of horizontal openings.
Designation (starting at bottom):
Frame type 6x4

VERTICAL MULTIPLE FRAMES

Vertical multiple frames are described by listing the bottom frame type and size + the next frame type and size.
Designation (starting at bottom):
(frame type) 6+6+4 and (frame type) 6+4+2


VERTICAL AND HORIZONTAL MULTIPLE FRAMES

List the entire vertical frames x the desired number of horizontal repetitions.
Designation (starting at bottom):
(frame type) 6+4+2x4


NOTE: All multiple frame designations must be preceded by the frame type.

NOTE: All multiple frame designations must be preceded by the frame type.

Components Ex

Ex and ATEX requirements are very strict, some Ex Insert blocks may not be approved with certain systems.

 

  • All blocks marked with black or green marking.
  • Ex system combined with EMC has yellow marking on the front face (see EMC instructions) and black or green on the back.

Ex Insert Blocks (IECEx/ATEX)

Standard Block Ex

Standard Block Ex

Standard Block Ex for high risk ATEX environments.

Read more
Addblock Ex

AddBlock Ex

Addblock Ex for high risk ATEX environments.

Read more
Spare Block Ex

Spareblock Ex

Spareblock Ex for high risk ATEX environments.

Read more

Components

Lubricant

MCT Brattberg Lubricant for easier and safer installation.

Read more

PTG Presswedge

The Presswedge compresses the system and completing the seal.

Read more

E-PTG Presswedge

The Presswedge with EMC and G&B capabilites compresses the system and completing the seal.

Read more

Stayplate

To be placed between each row of blocks.

Read more